How to Fix a Honeywell Quietset Tower Fan?

The Honeywell quietset tower fan is one of the best appliances you would want to have in your home. It gives your room a gentle breeze, making it comfortable to sit around even on a hot day. Some of its notable features include its slim design and remote control that allows you to select different cooling options at the comfort of your sofa.

Top Recommended Honeywell Quietset Tower Fans

 

How to Fix a Honeywell Quietset Tower Fan?

But what happens when your Honeywell quietset tower fan breaks and the heat is just too much to handle? Well, here are a few suggestions on how to fix Honeywell quietset tower fan.

how to fix honeywell quietset tower fan

Step 1

Make sure that is not plugged in before making any repair. If the fan’s head is not moving or is making noises when it’s on, consider looking at the gears on the clutch knob. They may be loose or worn out. Keep the head stationary if you opt not to replace the clutch knob or the gears.

Step 2

The next step involves removing the fan’s grill. Then, take off the clamps, nuts, or pins to detach the blade assembly from the fan’s motor. Finally, take away the blade assembly.

Step 3

Inspect the Honeywell quietset tower fan’s shaft, motor housing, grill, and blades to determine if dirt has accumulated. If any of the parts need cleaning, use a soft brush or a cloth to remove the debris. When done, make sure to safely secure the motor housing by tightening it.

Step 4

Make sure that the set screw, which balances the fan’s blades, is not damaged or worn out. And if it is loose, tighten it so that the blades move properly.

Step 5

Check the gear assembly and motor housing. Replace either of the two parts if they are loose or worn out.

Step 6

This final step involves assembling the fan when you are done tightening the gear assembly and motor housing. Finally, using turbine oil or household lubricant oil, lubricate the Honeywell quietset tower fan’s shaft.

 

Common Issues in Honeywell Quietset Tower Fans and How to Fix Them

When using the Honeywell quietset tower fan, you should follow the basic precautions to reduce the risk of fire, electric shock, damage of the appliance, and sustaining injuries. Although the breaking down of your favorite fan could be unprecedented, there are simple ways you can fix that.

It is advisable that you carefully read the manual and repair guide before conducting diagnostics. This will give you a rough idea of what you are dealing with and the necessary precautions to take.

best honeywell quietset tower fans

Fan Not Turning On

If you notice that your fan is not turning on, please ensure that your fan is properly plugged into the socket. Make sure your cord does not run under a carpet. Similarly, cords should not be routed under appliances or furniture. This appliance has a plug where one blade is wider than the other (polarised). This plug is intended to only fit in one way in a polarised socket. If the plug does not fit appropriately in the socket, reverse the plug.

Remember, a loose fit between the AC outlet and plug may cause overheating and a distortion of the plug. Please contact a qualified electrician to replace a worn outlet. The fan cord should be taken care of. Read the user manual for more instructions. Please contact a qualified electrician if any further complications arise.

When disconnecting, turn the unit off, grip the plug and pull it from the socket. You should not pull the plug by the cord.

Short-Circuiting

This is a common complication in electrical appliances. In the case of short-circuiting, replace the fuse with the recommended ones from the manufacturer’s guide. A fuse is a miniature electrical device, usually in the plug, that cuts the flow of electrical current when it is overloaded. This prevents the fan from being damaged by too much electric current.

To replace a blown fuse, first, remove the spare fuse holder attached to the cord. Remove the spare fuse from the plastic spare fuse holder and set the spare fuse aside. You can gain access to the blown fuse by sliding open the door found on the side of the plug. Slide the door outward until the blown fuse is fully visible. Carefully remove the blown fuse and snap the replacement fuse in place.

To protect the appliance against electric shock, do not place it in a window nor immerse the unit and its plug in water.

Buttons/Remote Control Not Working

Stuck buttons on the front panel are likely as a result of dirt accumulating under them. Ensure first that neither the remote nor the front panel start the fan. Only use one option. Always ensure that there is a clear line of sight between the remote and the IR receiver on the fan. Please check the repair guide for the guidelines. If the problem persists, it is advisable to replace the motor assembly. Do the same for the remote’s circuit board if it is not functional. You may also need to replace the batteries if the remote is not working. Do not mix old and new batteries. Also, do not mix rechargeable, standard or alkaline batteries.

Always keep an extra pack of batteries just in case. Remember to store the remote in the recessed area located behind the controls when not in use.

Obstructed Fan Blade

This problem arises when material blocks the fan mechanism making it immovable. The fan may make noise but produce no air. To solve this problem, open the fan and remove any objects obstructing the fan. Do this with extreme caution and use appropriate tools.

If your tower squeals, then here are surfaces rubbing against each other. Listen carefully to identify the source of the noise. Check and double-check all-access screws and make sure everything is in its rightful place. Most times it might be an object stuck in between your fan housing and center shaft. You may need to take it asunder and clean it.

Avoid contact with moving fan parts to prevent such problems.

Faulty Oscillation Monitor

In this case, you may need to replace the faulty oscillation monitor. If you can do it on your own, buy the monitor from a reputable dealer and repair it on your own. Alternatively, you can hire a technician to do it for you.

 

Conclusion

Always remember to first read all instructions before attempting to use the Honeywell quietset tower fan. The appliance comes with a one-year warranty, which applies to repair or replacement of the fan in case of any defects. Most importantly, carry out regular maintenance to enhance the efficiency of your fan.